Order No. 1461 on regulation air pollution from combustion plants for solid fuel below 1 MW.
Country
Type of law
Regulation
Abstract
This Order applies to combustion plants for solid fuels with a total rated thermal input below 1 MW. Combustion plants may only be marketed, transferred or connected when they meet the limit values of Appendix 1 with regard to heaters and Appendix 2 with regard to central heating boilers. Measurements used for documentation of compliance with the limit values in Appendices 1-2 must be carried out by accredited laboratory testing institutions in accordance with relevant standards for combustion plants, as well as for the determination of chemicals present in waste gas by accredited Danish Accreditation and Metrology Fund or an equivalent accreditation body which is signatory to the EA or ILAC multilateral agreement mutual recognition.
The Order consists of 9 Chapters and 2 Appendices: Scope and definitions (1); Requirements for combustion plants (2); Measurements and certificates (3); Maximum of exhaust system (4); Particular on central heating boilers with a rated thermal input of more than 120 kW (5); Monitoring (6); Municipal regulations (7); Penalty (8); Entry into force and transitional provisions (9).
Appendix 1 - Limits/emission requirements for heaters.
Appendix 2 - Limit/emission requirements for central heating boilers 0 to 1 MW.
The Order consists of 9 Chapters and 2 Appendices: Scope and definitions (1); Requirements for combustion plants (2); Measurements and certificates (3); Maximum of exhaust system (4); Particular on central heating boilers with a rated thermal input of more than 120 kW (5); Monitoring (6); Municipal regulations (7); Penalty (8); Entry into force and transitional provisions (9).
Appendix 1 - Limits/emission requirements for heaters.
Appendix 2 - Limit/emission requirements for central heating boilers 0 to 1 MW.
Attached files
Date of text
Entry into force notes
31 December 2015.
Notes
Combustion equipment placed on the market, transferred or connected, must first comply with the limits listed in Appendices 1-2 from 26 July 2015.Straw boilers in rural zones must first comply with the limits for particulate matter (dust), CO, OGC (see Appendix 2) from 26 January 2018. However, if they measure up to 300 kW, they continue to meet the requirements for CO and OGC in boiler class 3 standard EN 303-5 or similar.Firing installations, including fireplace inserts that without the aid of series-manufactured prefabricated sections of the building or made to measure for a specific location, must first meet the requirements of the notice from 26 January 2017.History heaters (produced before 1940) and individually produced copies of historical heaters not installed in buildings that have been listed under the Preservation of Buildings Act, or in buildings that are covered by the Museums Act Appendix 1, must first meet the requirements of the Order of 26 January 2017.